- #SIEMENS SINUTRAIN ACTIVATE OPTION INSTALL#
- #SIEMENS SINUTRAIN ACTIVATE OPTION PASSWORD#
- #SIEMENS SINUTRAIN ACTIVATE OPTION LICENSE#
Do NOT close this window! CONFIGURE USERS When you run the free version of SinuTrain for SINUMERIK Operate V4.7 you do NOT have access to the OPC UA configuration soft key at the controller. If configured correctly on startup of the machine now an additional command line window opens that shows details about the activities of miniweb.exe. At the end add: PROC100= image:="c:\siemens\sinutrain\sinumerik CNC-SW 840D sl 4.7 SP3 HF1\hmi\siemens\sinumerik\hmi\miniweb\release\miniweb.exe", process:=miniwebserver, cmdline:=".\system.\still contains the additional process. Open file C:\Siemens\SinuTrain\SINUMERIK CNC-SW 840D sl 4.7 SP3 HF1\hmi\user\sinumerik\hmi\cfg\systemconfiguration.ini with a text editor. This user is administrator of the OPC UA server and has the right to read and write all items at the controller.
#SIEMENS SINUTRAIN ACTIVATE OPTION PASSWORD#
Add file UserDataBase.xml (from the.zip archive) to directory C:\Siemens\SinuTrain\SINUMERIK CNC-SW 840D sl 4.7 SP3 HF1\hmi\siemens\sinumerik\hmi\miniweb\System\UserDataBase\ File UserDataBase.xml contains entries for OPC UA user OpcUaClient with Password OpcUaClient. Copy ALL files from folder C:\Siemens\SinuTrain\SINUMERIK CNC-SW 840D sl 4.7 SP3 HF1\hmi\siemens\sinumerik\hmi\template\cfg\miniweb\ to folder C:\Siemens\SinuTrain\SINUMERIK CNC-SW 840D sl 4.7 SP3 HF1\hmi\user\sinumerik\hmi\miniweb\cfg\ Open UAApplication.xml with a text editor and replace all localhost entries in this file with the IPv4 address of your PC.
#SIEMENS SINUTRAIN ACTIVATE OPTION LICENSE#
Click - > -, enter OPC, activate the license and click. Lathe with driven tool, it is recommended NOT to use the DEMO-Lathe device. Start SinuTrain and create one new machine f.i. If you accept all default settings you are able to use the paths mentioned below.
![siemens sinutrain activate option siemens sinutrain activate option](https://academy.simumatik.com/learn/ThirdParty/PLC/images/image_3.png)
#SIEMENS SINUTRAIN ACTIVATE OPTION INSTALL#
Download and install SinuTrain for SINUMERIK Operate V4.7 Ed.2 - Basic. You have to register a free account to be able to download the program. CONTROLLER SETUP (SINUTRAIN) OPC UA setup on the free version of SinuTrain for SINUMERIK Operate V4.7 Ed.2 differs a bit from the procedure on a real controller but exactly works in the same way. \siemens\sinumerik\hmi\template\cfg\miniweb\ Restart the controller. If files are missing, copy them to this directory from. \user\sinumerik\hmi\miniweb\cfg\: AddressModeller.xml, OPC_UAApplication.xml, SinumerikOemConfiguration.xml and TraceConfig.xml. of 10ģ Make sure that the following files are in folder. \siemens\sinumerik\hmi\miniweb\system\ and verify that it contains file UserDataBase.xml. With Windows Explorer navigate to folder. Important note: Please ensure that the date and time on your HMI is correct, otherwise certificate based OPC UA authentication does not work! Shut down the controller and start it in service mode without HMI. For testing it is also recommended to use OpcUaClient. Enter and confirm the password for this user (3).
![siemens sinutrain activate option siemens sinutrain activate option](https://lasopadv897.weebly.com/uploads/1/2/6/5/126523098/761495255.jpg)
Enter 4840 in field Port (2) Enter a username for the Administrator (2) of the OPC UA server on the controller, for testing it is recommended to use OpcUaClient. 2 Start the OPC UA configuration in area ->-> FIG 2: Configure OPC UA IP Address is automatically set according to the HMI configuration, -X130 for NCU and PPU Local Area Connection 2 for PCU 50.